The Aquapump XL is available as a Mono or Duo system with pumps in different performance classes, which can be designed for faecal and faecal-free wastewater. Many upper sections made of different materials ensure that the pumping station can be installed flexibly as a wet or dry installation at different installation locations.

Advantages  Product overview

The right pump for all cases

Whether a small or large usable volume, Mono or Duo system, with a multi-vane vortex impeller or single channel impeller or an additional macerator: The Aquapump XL can be equipped with a wide variety of pumps for faecal or faecal-free wastewater. This opens up countless possibilities to tailor the pumping station to individual needs.

Flexible modular system

The Aquapump XL has been designed as a modular system and can be variably combined with technical and chamber modules. What this means for you: You can select the perfect drainage solution from a wide range of modules and upper sections – whether for underground or floor slab installation. Our standard engineering chambers are groundwater-resistant up to three metres and can be built up to a height of five metres.

To the engineering chambers

Practical and hygienic

In comparison with the wet installation in pumping stations for faecal wastewater, the dry installation offers mainly hygienic advantages for maintenance and repairs since the pumping stations has a separate collecting chamber. In addition, pumps do not require ATEX approval for dry installation.

Reliable control

The intelligent control unit with the integrated SDS self-diagnosis system and battery backup continuously checks all electrical components and keeps a readable, electronic operating log book.

Maximum safety

The pumping stations for faecal wastewater can be operated in potentially explosive areas – This means at locations where explosive gases may occur due to faecal wastewater and/or light liquids.

Pumping station Aquapump XL dry' installation

Type of wastewater: wastewater without sewage

Pump: GTF 600

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743004 230  VLT in combination with a chamber module S1 Single station Float switch 90  LTR Multi-vane impeller Wet installation 8743004
Show
8743005 230  VLT in combination with a chamber module S1 Single station Submersible pressure switch 90  LTR Multi-vane impeller Wet installation 8743005
Show
8743007 230  VLT in combination with a chamber module S1 Twin pump station Submersible pressure switch 90  LTR Multi-vane impeller Wet installation 8743007
Show

Pump: GTF 1200

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743009 230  VLT in combination with a chamber module S3 - 50 % Single station Float switch 100  LTR Multi-vane impeller Wet installation 8743009
Show
8743010 230  VLT in combination with a chamber module S1 Single station Submersible pressure switch 100  LTR Multi-vane impeller Wet installation 8743010
Show
8743012 230  VLT in combination with a chamber module S1 Twin pump station Submersible pressure switch 100  LTR Multi-vane impeller Wet installation 8743012
Show

Pump: GTF 1400

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743032-- S1 Single station Float switch 210  LTR Multi-vane impeller Wet installation 8743032
Show
8743033 230  VLT - S1 Single station Level sensor 350  LTR Multi-vane impeller Wet installation 8743033
Show
8743034 230  VLT - S1 Twin pump station Level sensor 340  LTR Multi-vane impeller Wet installation 8743034
Show

Pump: GTF 1600

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743020 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Multi-vane impeller Wet installation 8743020
Show
8743023 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Multi-vane impeller Wet installation 8743023
Show

Pump: GTF 2600

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743021 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Multi-vane impeller Wet installation 8743021
Show
8743024 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Multi-vane impeller Wet installation 8743024
Show

Pump: GTF 4000

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743022 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Multi-vane impeller Wet installation 8743022
Show
8743025 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Multi-vane impeller Wet installation 8743025
Show

Pump: GTK 1300

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743026 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Single-vane impeller Wet installation 8743026
Show
8743029 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Single-vane impeller Wet installation 8743029
Show

Pump: GTK 2600

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743027 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Single-vane impeller Wet installation 8743027
Show
8743030 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Single-vane impeller Wet installation 8743030
Show

Pump: GTK 3700

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743028 400  VLT in combination with a chamber module S1 Single station Level sensor 350  LTR Single-vane impeller Wet installation 8743028
Show
8743031 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 340  LTR Single-vane impeller Wet installation 8743031
Show

Type of wastewater: wastewater with sewage

Pump: GTF 1400

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743047 400  VLT - S1 Single station Level sensor 350  LTR Multi-vane impeller Wet installation 8743047
Show
8743048 400  VLT - S1 Twin pump station Level sensor 350  LTR Multi-vane impeller Wet installation 8743048
Show

Pump: SPF 1400

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8742000 230  VLT Version for deeper installation S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742000
Show
8742004 230  VLT Version for deeper installation S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742004
Show
8742008 230  VLT Version for deeper installation S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742008
Show
8742012 230  VLT Version with lowest installation height S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742012
Show
8742016 230  VLT Version with lowest installation height S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742016
Show
8742020 230  VLT Version with lowest installation height S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742020
Show

Pump: SPF 1500

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8742001 400  VLT Version for deeper installation S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742001
Show
8742005 400  VLT Version for deeper installation S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742005
Show
8742009 400  VLT Version for deeper installation S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742009
Show
8742013 400  VLT Version with lowest installation height S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742013
Show
8742017 400  VLT Version with lowest installation height S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742017
Show
8742021 400  VLT Version with lowest installation height S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742021
Show

Pump: SPF 3000

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8742002 400  VLT Version for deeper installation S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742002
Show
8742006 400  VLT Version for deeper installation S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742006
Show
8742010 400  VLT Version for deeper installation S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742010
Show
8742014 400  VLT Version with lowest installation height S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742014
Show
8742018 400  VLT Version with lowest installation height S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742018
Show
8742022 400  VLT Version with lowest installation height S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742022
Show

Pump: SPF 4500

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8742003 400  VLT Version for deeper installation S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742003
Show
8742007 400  VLT Version for deeper installation S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742007
Show
8742011 400  VLT Version for deeper installation S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742011
Show
8742015 400  VLT Version with lowest installation height S3 - 50 % Single station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742015
Show
8742019 400  VLT Version with lowest installation height S3 - 50 % Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742019
Show
8742023 400  VLT Version with lowest installation height S1 Twin pump station Immersion pipe 160  LTR Multi-vane impeller Dry installation 8742023
Show

Pump: STZ 1300

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743014 400  VLT in combination with a chamber module S1 Single station Level sensor 310  LTR Macerator Wet installation 8743014
Show
8743017 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 300  LTR Macerator Wet installation 8743017
Show

Pump: STZ 2500

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743015 400  VLT in combination with a chamber module S1 Single station Level sensor 310  LTR Macerator Wet installation 8743015
Show
8743018 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 300  LTR Macerator Wet installation 8743018
Show

Pump: STZ 3700

Operating voltageNote on installation depthOperating modeType of systemLevel measurement instrumentPumping volumeImpeller typeInstallation Item no.
8743016 400  VLT in combination with a chamber module S1 Single station Level sensor 310  LTR Macerator Wet installation 8743016
Show
8743019 400  VLT in combination with a chamber module S1 Twin pump station Level sensor 300  LTR Macerator Wet installation 8743019