Skip to main content

Lifting station Aqualift S Compact

Duo, GTF 500, resistant, Floor sl., tileable

The ready to plug in lifting station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank. One-handed closures enable easy removal of the integrated components. The system for installation in the floor slab is preassembled for final installation on site. The station is controlled optionally by a float switch (Mono) or a user-friendly control unit (Tronic and Duo), which are optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface. - with telescopic upper section for continuously adjustable height and level compensation and integrated floor drain - collection tank made of PE, resistant to aggressive wastewater and 3 m groundwater - including backflow preventer for the pressure pipe - including sockets for inlet and cable conduit - pump with multi-vane impeller for maximum operating reliability

  • System resistant to media containing salt and wastewater from water softening units
  • System ready to plug in
  • Quiet operation, as the pump installation does not cause any structure-borne sound emissions.
Item no. 280530XC
GTIN 4026092082713
Price group 20

Lifting station Aqualift S Compact Duo, GTF 500, resistant, Floor sl., tileable
The ready to plug in lifting station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank. One-handed closures enable easy removal of the integrated components. The system for installation in the floor slab is preassembled for final installation on site. The station is controlled optionally by a float switch (Mono) or a user-friendly control unit (Tronic and Duo), which are optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface. - with telescopic upper section for continuously adjustable height and level compensation and integrated floor drain - collection tank made of PE, resistant to aggressive wastewater and 3 m groundwater - including backflow preventer for the pressure pipe - including sockets for inlet and cable conduit - pump with multi-vane impeller for maximum operating reliability Type of wastewater: wastewater without sewage Installation situation: floor slab installation Version: Type of system: Twin pump station Pump control: Control unit Backflow preventer: integrated Resistant: Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems Delivery state: Installation-ready (connection parts must be connected on site) General characteristics: Colour: black Standard: EN 12050-2 Dimensions: Length: 617 mm Width: 585 mm Tank: Inlet nominal size (DN): 100 Pumping volume: 20 l Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Installation depth: 490 - 620 mm Vertical adjustment: vertically adjustable upper section Coverage features: Type of cover: tileable cover plate Cover material: Polymer Colour of cover: silver grey Drainage function: yes Max. flooring height: 16 mm Load class: K 3 (EN 1253-1) Length: 366 mm Width: 366 mm Locking: Lock & Lift Free passage: 10 mm Pumping device: Pump: GTF 500 resistant Number of pumps: 2 Max. pumping capacity: 10 m3/h Max. pumping height: 8 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 0.6 kW Power P2: 0.36 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 (3m) Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Protection class control unit: IP 54 Connection type: coded plug Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: optical probe

Video

  Title Item no.  
  Title Item no.  
  Title Item no.  
Remote signal generator 20 m cable, 2x0.75 q 20162 Show
Basic warning device with electronic probe 20222 Show
Basic warning device with optical probe 20223 Show
Adapter DN 50/70 27126 Show
Adapter DN 100/70 27602 Show
Retrofit kit Alarm float switch 28016 Show
Pressure pipe set 5 m pressure hose, DA 40 mm 28040 Show
Compressor set for air bubbling 28048 Show
Pressure pipe set with 5 m pressure hose, DA 50 mm 28062 Show
Adapter for pressure connection PE DA40 28086 Show
TeleControl GSM modem for Comfort control units 230V/400V 28792 Show
Aerial with magnetic base for TeleControl Modem, Cable 2.5 m 28793 Show
Extension cable for aerial with magnetic base, L: 2 m 28794 Show
Inlet socket DN 50, with seal, Threaded ring 39005 Show
Inlet socket DN 70, with seal, Threaded ring 39007 Show
Inlet socket DN 100, with seal, Threaded ring 39100 Show
Odour trap Multistop, System 125 48500 Show
Odour trap Megastop 48550 Show
Hair filter Polymer, for System 125 bathroom drains 48700 Show
Hole saw for DN 50/70/100 500101 Show
Pressure hose Sold by the metre, 6x4 mm 100 680071 Show
Odour trap for The Ultraflat 79 680696 Show
Drain body for cover plate for odour trap 50 mm, black 680795 Show
Drain body for cover plate for Multistop, black 680796 Show
Drain body for cover plate for odour trap 50 mm, grey 680797 Show
Drain body for cover plate for Multistop, grey 680798 Show
Potential-free contact Additional circuit board for control units. 80072 Show
Potential-free contact Extension set for control units Basic 80074 Show
10 m probe cable extension set 80889 Show
Cable prolongation set for pump 10 m 80891 Show
Cover, watertight, black 830050 Show
Cover, watertight, tile-over 830052 Show
Extension section H: 200 mm 83070 Show
Extension section H: 234 mm, with flange and counter-flange 83073 Show
Extension section H: 360 mm, with central flange 83075 Show
Waterproof concrete install. kit OD: 40 mm, for building contractors 83077 Show
Seal for pipe penetration, DN 50 850114 Show
Seal for channel passage 75 mm 850116 Show
Seal for channel passage 110 mm 850117 Show
  Title Item no.  
Splash guard set for optical probe 28706 Show
Control unit Aqualift Comfort 230 V Duo 28746 Show
Inlet socket DN 50, with seal, Threaded ring 39005 Show
Locking key for Ecoguss slotted gratings, Lock & Lift 67007 Show
One-handed closure for backflow preventer 680018 Show
Battery 9 V block 680034 Show
Pressure hose Sold by the metre, 6x4 mm 100 680071 Show
Seal for upper section, from 07/2014 680150 Show
Cover tileable, Lock & Lift, ABS 680224 Show
Pump connection with seal and flap 680475 Show
Release key for Lock & Lift 680702 Show
Pressure pipe connection with seal and screws 680758 Show
Pump connection Minilift, Aqualift S 680760 Show
Turn fastener for pump connection lock 680762 Show
Replacement pump GTF 500 resistant, without float switch 680774 Show
Immersion pipe level measurement for Aqualift S Compact 680776 Show
Fixing for immersion pipe for Aqualift S, Fastening clip, Screw 680777 Show
Fixing for sensor for Aqualift S, Fastening clip, Screw 680778 Show
Pump hanger for Aqualift S Compact, Duo, GTF 500 680779 Show
Flap housing Duo, with pump connector 680781 Show
Seal for cover plate, System 330 mm 686114 Show
Replacement set optical probe 80888 Show
Adapter set optical probe 80892 Show
KESSEL cover pl, tileable drainage funct 830054 Show
Upper section System 400 830065 Show
  • Free passage (ATTR-180): 10  MMT
  • TÜV test mark (ATTR-376): ID 1111241937
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): Freestanding pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Polymer
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 1/N/PE 230V
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 800  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 6.9  AMP
  • Vertical installation (ATTR-286): yes
  • Operating mode, twin systems (ATTR-287): redundant
  • Pump (ATTR-4): GTF 500 resistant
  • Number of pumps (ATTR-181): 2
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Type of fuse required (electrical protection) (ATTR-N3): C 16 A
  • Operating mode (ATTR-10): S1
  • Power P1 (ATTR-F4): 0.6  KWT
  • Power P2 (ATTR-F5): 0.4  KWT
  • Speed (ATTR-F2): 2,800  UMIN
  • Operating voltage (ATTR-131): 230  VLT
  • Mains frequency (ATTR-N4): 50  HTZ
  • Rated current (ATTR-N5): 2.7  AMP
  • Max. pumping capacity (ATTR-F7): 10  MQH
  • Max. pumping height (ATTR-F8): 8  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Connection type (ATTR-N1): coded plug
  • Protection class (pump) (ATTR-125): IP 68 (3m)
  • Length of mains cable for pump (ATTR-11): 5  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Net weight (ATTR-A3A): 19.3  KGM
  • Gross weight (ATTR-A3B): 20.8  KGM
  • Type of system (ATTR-2): Twin pump station
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Control unit
  • Resistant (ATTR-338): Resistant to saline media, wastewater from water softening systems and wastewater containing condensate from heating systems
  • Type of cover (ATTR-A21): tileable cover plate
  • Colour of cover (ATTR-A2A): silver grey
  • Load class (ATTR-A2B): K 3 (EN 1253-1)
  • Locking (ATTR-A2D): Lock & Lift
  • Cover material (ATTR-A2E): Polymer
  • Drainage function (ATTR-A2H): yes
  • Max. flooring height (ATTR-A2L): 16  MMT
  • Length (ATTR-A2M): 366  MMT
  • Width (ATTR-A2N): 366  MMT
  • Inlet nominal size (DN) (ATTR-B1CA): 100  MMT
  • Installation depth (ATTR-B2_VB): 490  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 32  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 40  MMT
  • Pumping volume (ATTR-B10): 20  LTR
  • Length (ATTR-A6A): 617  MMT
  • Width (ATTR-A6B): 585  MMT
  • Volume (ATTR-320): 0.2  MTQ
  • Packaging dimension: length (ATTR-325): 600  MMT
  • Packaging dimension: width (ATTR-326): 600  MMT
  • Packaging dimension: height (ATTR-327): 480  MMT
  • Dimensions (ATTR-323): 600X600X480MM
  • Number of packages (ATTR-321): 1
  • Control unit (ATTR-S2): Comfort
  • Self-diagnosis system (SDS) (ATTR-S5): yes
  • Battery buffering (ATTR-S6): yes
  • Multi-line display (ATTR-S7): yes
  • Log book function (ATTR-S8): yes
  • USB interface (ATTR-S9): yes
  • GSM interface (ATTR-S10): yes
  • Potential-free contact (ATTR-S11): optional
  • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
  • Connection type (ATTR-S19): coded plug
  • Operating voltage (ATTR-S13): 230  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Protection class control unit (ATTR-S4): IP 54
  • Alarm sensor (ATTR-S1): optical probe
  • Type of level measurement (ATTR-7A): pneumatic
  • Level measurement instrument (ATTR-7B): Immersion pipe
  • Installation situation (ATTR-1): floor slab installation
  • Vertical adjustment (ATTR-177): vertically adjustable upper section
  • Declaration of Performance (DOP) (ATTR-292): 009-085
  • Wastewater quantity (ATTR-310): Medium
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Declaration of conformity (ATTR-303): 009-076
  • Colour (ATTR-102): black
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Delivery state (ATTR-189): Installation-ready (connection parts must be connected on site)
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Lifting station
  • Product family (M-ATTR-004): Aqualift S
  • Product name (M-ATTR-005): Aqualift S Compact
  • Startup circuit for three-phase connection or three-phase current (ATTR-278):