Skip to main content

Replacement pump AqualiftF/Pumpfix F

Item no. 28351
GTIN 4026092038420
Price group 90

    Type of wastewater: wastewater with sewage Version: Pump control: Control unit General characteristics: Standard: EN 12050-1 Pumping device: Pump: SPZ 1000 Max. pumping capacity: 12 m3/h Max. pumping height: 10 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S3 - 50 % Power P1: 1.2 kW Power P2: 0.7 kW Speed: 2,800 U/min Type of fuse required (electrical protection): Fuse protection through control unit 230 V Max. temperature (permanent) of conveyed material: 35 °C Connection type: coded plug Impeller type: Macerator Length of mains cable for pump: 5 m Rated current: 5.2 A Protection class (pump): IP 68 (3m/48h) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.97 Insulation class: F
      Title Item no.  
      Title Item no.  
      Title Item no.  
      Title Item no.  
    KTP1000 cutting assembly replacement set 28075 Show
    Impeller KTP/SPZ 1000, without intake cover 680035 Show
    Catalog Page
    • Type of wastewater (ATTR-6): wastewater with sewage
    • Net weight (ATTR-A3A): 10.3  KGM
    • Gross weight (ATTR-A3B): 10.6  KGM
    • Standard (ATTR-9): EN 12050-1
    • Pump control (ATTR-134): Control unit
    • Pump (ATTR-4): SPZ 1000
    • Impeller type (ATTR-8): Macerator
    • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
    • Type of fuse required (electrical protection) (ATTR-N3): Fuse protection through control unit 230 V
    • Max. permissible switching frequency (ATTR-162): 20  1PH
    • Operating mode (ATTR-10): S3 - 50 %
    • Power P1 (ATTR-F4): 1.2  KWT
    • Power P2 (ATTR-F5): 0.7  KWT
    • Speed (ATTR-F2): 2,800  UMIN
    • Operating voltage (ATTR-131): 230  VLT
    • Mains frequency (ATTR-N4): 50  HTZ
    • Rated current (ATTR-N5): 5.2  AMP
    • Max. pumping capacity (ATTR-F7): 12  MQH
    • Max. pumping height (ATTR-F8): 10  MTR
    • Max. temperature (permanent) of conveyed material (ATTR-132): 35  CEL
    • Protection class (ATTR-133): I
    • Connection type (ATTR-N1): coded plug
    • Protection class (pump) (ATTR-125): IP 68 (3m/48h)
    • Length of mains cable for pump (ATTR-11): 5  MTR
    • Temperature monitoring (ATTR-135): integrated
    • Cos phi - power factor (ATTR-192): 1.0
    • Insulation class (ATTR-193): F
    • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
    • Expected service life (number of switching cycles) (ATTR-195): 150,000
    • Country of origin (ATTR-322): DE