Lifting station Aqualift S
Duo, KTP 500-S1, Free-standing set-up


The lifting station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options. One-handed closures enable easy removal of the integrated components. The station is controlled optionally by a float switch (Mono) or a user-friendly control unit (Tronic and Duo), which are optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface.
- System ready to plug in
- One-handed closures enable easy removal of the integrated components
- Control unit with self-diagnosis system
Item no. | 28541-C |
---|---|
GTIN | 4026092058534 |
Price group | 20 |
Lifting station Aqualift S Duo, KTP 500-S1, Free-standing set-up
The lifting station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank made of permanently resistant polymer (PE) offers universal connection options. One-handed closures enable easy removal of the integrated components. The station is controlled optionally by a float switch (Mono) or a user-friendly control unit (Tronic and Duo), which are optionally integrated in the building management system via a potential-free contact or alarm and collective fault messages can be output via a GSM interface. Type of wastewater: wastewater without sewage Installation situation: free-standing set-up Version: Type of system: Twin pump station Pump control: Control unit Backflow preventer: integrated Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected) General characteristics: Colour: black Standard: EN 12050-2 Dimensions: Length: 500 mm Width: 500 mm Height: 720 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 100 Inlet nominal size (OD): 110 mm Inlet max. scoring (DN): 100 mm Distance pipe bottom inlet to tank bottom: 530 mm Distance from centre of outlet pipe to tank bottom: 258 mm Distance from centre of inlet pipe to tank bottom: 585 mm Tank volume: 55 l Pressure pipe connection: horizontal Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Venting connection (DN): 70 mm Coverage features: Cover material: Polymer Colour of cover: black Length: 420 mm Width: 420 mm Height: 70 mm Locking: wedged Free passage: 10 mm Pumping device: Pump: GTF 500 Number of pumps: 2 Max. pumping capacity: 10 m3/h Max. pumping height: 8 m Operating voltage: 230 V Mains frequency: 50 Hz Operating mode: S1 Power P1: 0.6 kW Power P2: 0.36 kW Speed: 2,800 U/min Type of fuse required (electrical protection): C 16 A Max. temperature (permanent) of conveyed material: 40 °C Connection type: Schuko (earthed contact) 2-pin Weight: 6 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 5 m Rated current: 2.7 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.91 Insulation class: F Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): C 16 A Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Immersion pipe Alarm sensor: optical probe
Installation Video
Title | Item no. |
---|
Title | Item no. |
---|
Title | Item no. | ||
---|---|---|---|
![]() | Remote signal generator 20 m cable, 2x0.75 q | 20162 | Show |
![]() | Basic warning device with electronic probe | 20222 | Show |
![]() | Basic warning device with optical probe | 20223 | Show |
![]() | Pressure pipe set 5 m pressure hose, DA 40 mm | 28040 | Show |
![]() | Potential-free contact Additional circuit board for control units. | 80072 | Show |
![]() | 10 m probe cable extension set | 80889 | Show |
![]() | Cable prolongation set for pump 10 m | 80891 | Show |
Title | Item no. | ||
---|---|---|---|
![]() | Non-return flap valve for KTP 300 | 27207 | Show |
![]() | Lifting nut | 28011 | Show |
![]() | Aqualift-DUO Pump locking set | 28032 | Show |
![]() | Control unit Aqualift Comfort 230 V Duo | 28746 | Show |
![]() | Screw set for pressure switch, 4 ea. | 680006 | Show |
![]() | One-handed closure for backflow preventer | 680018 | Show |
![]() | Rubber nipple DN 40 | 680020 | Show |
![]() | Cover LW 400, freestanding set-up | 680031 | Show |
![]() | Bracket Immersion pipe | 680032 | Show |
![]() | Battery 9 V block | 680034 | Show |
![]() | Immersion pipe Duo, 5 m, from 01/2010 | 680056 | Show |
![]() | Multi-vane impeller for GTF 500 | 680767 | Show |
![]() | Spiral housing for GTF 500 | 680768 | Show |
Screw set for intake cage, GTF 500 | 680769 | Show | |
![]() | Intake cage for GTF 500 | 680770 | Show |
![]() | Replacement pump GTF 500 without float switch | 680877 | Show |
![]() | Replacement set optical probe | 80888 | Show |
![]() | Adapter set optical probe | 80892 | Show |
![]() | Seal d: 368 mm | 850112 | Show |
![]() | Seal d: 458 mm | 850113 | Show |
- Declaration of Performance (DOP) (ATTR-292): 009-002
- Country of origin (ATTR-322): DE
- Area of application (ATTR-264): drainage
- Pump type (ATTR-265): Freestanding pump
- Pump shaft position (ATTR-266): vertical
- Pump design (ATTR-267): Dry rotor pump
- Pump hydraulics (ATTR-268): single stage
- Pump suction characteristic (ATTR-269): non-self-priming
- Pump drive (ATTR-270): E-motor for alternating current
- E-motor, type of startup (ATTR-271): direct
- Pump casing material (ATTR-272): Polymer
- Upper tolerance of the operating voltage (+) (ATTR-273): 10 PROZ
- Lower tolerance of the operating voltage (-) (ATTR-274): 10 PROZ
- Upper tolerance of the nominal frequency (+) (ATTR-275): 3 PROZ
- Lower tolerance of the nominal frequency (-) (ATTR-276): 2 PROZ
- Pump electrical connection (ATTR-277): 1/N/PE 230V
- Motor pump shaft (ATTR-279): continuous
- Shaft seal (ATTR-280): RSSR
- Number of operating pumps (ATTR-281): 1
- Minimum pumped media temperature (ATTR-282): 0 CEL
- Maximum operating pressure (Pmax) (ATTR-283): 800 HPA
- Minimum speed for speed adjustment (ATTR-284): no speed adjustment
- Start-up current (ATTR-285): 6.9 AMP
- Vertical installation (ATTR-286): yes
- Operating mode, twin systems (ATTR-287): redundant
- Pump (ATTR-4): GTF 500
- Number of pumps (ATTR-181): 2
- Impeller type (ATTR-8): Multi-vane impeller
- Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
- Type of fuse required (electrical protection) (ATTR-N3): C 16 A
- Max. permissible switching frequency (ATTR-162): 20 1PH
- Operating mode (ATTR-10): S1
- Power P1 (ATTR-F4): 0.6 KWT
- Power P2 (ATTR-F5): 0.4 KWT
- Speed (ATTR-F2): 2,800 UMIN
- Operating voltage (ATTR-131): 230 VLT
- Mains frequency (ATTR-N4): 50 HTZ
- Rated current (ATTR-N5): 2.7 AMP
- Max. pumping capacity (ATTR-F7): 10 MQH
- Max. pumping height (ATTR-F8): 8 MTR
- Max. temperature (permanent) of conveyed material (ATTR-132): 40 CEL
- Protection class (ATTR-133): I
- Connection type (ATTR-N1): Schuko (earthed contact) 2-pin
- Protection class (pump) (ATTR-125): IP 68 (3m)
- Length of mains cable for pump (ATTR-11): 5 MTR
- Temperature monitoring (ATTR-135): integrated
- Weight (ATTR-191): 6 KGM
- Cos phi - power factor (ATTR-192): 0.9
- Insulation class (ATTR-193): F
- Expected service life (hours of operation) (ATTR-194): 3,000 HUR
- Expected service life (number of switching cycles) (ATTR-195): 150,000
- Pressure pipe connection (ATTR-B7): horizontal
- Type of system (ATTR-2): Twin pump station
- Backflow preventer (ATTR-165): integrated
- Pump control (ATTR-134): Control unit
- Control unit (ATTR-S2):
Comfort
- Self-diagnosis system (SDS) (ATTR-S5): yes
- Battery buffering (ATTR-S6): yes
- Multi-line display (ATTR-S7): yes
- Log book function (ATTR-S8): yes
- USB interface (ATTR-S9): yes
- GSM interface (ATTR-S10): yes
- Potential-free contact (ATTR-S11): optional
- Length of mains cable for control unit (ATTR-S12): 1.4 MTR
- Operating voltage (ATTR-S13): 230 VLT
- Mains frequency (ATTR-S14): 50 HTZ
- Protection class control unit (ATTR-S4): IP 54
- Alarm sensor (ATTR-S1): optical probe
- Type of level measurement (ATTR-7A): pneumatic
- Level measurement instrument (ATTR-7B): Immersion pipe
- Type of fuse required (electrical protection) (ATTR-S17): C 16 A
- Number of inlets (ATTR-B1B): 1 PCE
- Inlet nominal size (DN) (ATTR-B1CA): 100 MMT
- Inlet nominal size (OD) (ATTR-B1CB): 110 MMT
- Distance from centre of inlet pipe to tank bottom (ATTR-B6): 585 MMT
- Distance pipe bottom inlet to tank bottom (ATTR-B1D): 530 MMT
- Inlet max. scoring (DN) (ATTR-B1E): 100 MMT
- Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 258 MMT
- Venting connection (DN) (ATTR-B4): 70 MMT
- Pressure pipe connection (DN) (ATTR-B17): 32 MMT
- Pressure pipe connection (OD) (ATTR-B18): 40 MMT
- Tank volume (ATTR-B9): 55 LTR
- Colour of cover (ATTR-A2A): black
- Locking (ATTR-A2D): wedged
- Cover material (ATTR-A2E):
Polymer
- Length (ATTR-A2M): 420 MMT
- Width (ATTR-A2N): 420 MMT
- Height (ATTR-A2P): 70 MMT
- Length (ATTR-A6A): 500 MMT
- Width (ATTR-A6B): 500 MMT
- Height (ATTR-A6C): 720 MMT
- Volume (ATTR-320): 0.2 MTQ
- Packaging dimension: length (ATTR-325): 610 MMT
- Packaging dimension: width (ATTR-326): 610 MMT
- Packaging dimension: height (ATTR-327): 490 MMT
- Dimensions (ATTR-323): 610X610X490MM
- Number of packages (ATTR-321): 0
- Net weight (ATTR-A3A): 20.0 KGM
- Gross weight (ATTR-A3B): 21.7 KGM
- Installation situation (ATTR-1):
free-standing set-up
- Wastewater quantity (ATTR-310):
Medium
- Type of wastewater (ATTR-6):
wastewater without sewage
- Colour (ATTR-102): black
- Standard (ATTR-9): EN 12050-2
- CE marking (ATTR-A5B):
yes
- External monitoring (ATTR-A8): LGA
- Free passage (ATTR-180): 10 MMT
- Delivery state (ATTR-189): Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)
- Brand (M-ATTR-001): KESSEL
- Product group (M-ATTR-002): Lifting stations
- Product type (M-ATTR-003): Lifting station
- Product family (M-ATTR-004): Aqualift
- Product name (M-ATTR-005): Aqualift S